Introduction

Flow injection polymer analysis is a fast, automated technique for measuring molecular weight, molecular size and intrinsic viscosity of macromolecules. Depending on the sample, analysis times may be optimized to 6-10 samples per hour. Another bonus of FIPA measurements is minimal solvent and sample usage.

Applications

FIPA is a precise, accurate, and effective way to measure polymer properties for routine quality control or process development. The technique can be applied to a variety of aqueous or organic applications like: polyesters, polyamides, polycarbonates, proteins, polysaccharides etc.

Description

In FIPA the polymer or protein in solution is injected in a FIPA system with RI, light scattering and viscometer detectors. Unlike GPC/SEC, FIPA does not provide a distribution of information. Instead, the column technology in the FIPA experiment is used to separate the polymer or protein of interest from any low molecular weight constituents such as diluents, additives or salts that may be in the sample. The sample is measured as a single batch and the analysis takes only a few minutes.

FIPA uses advanced detector technology to fully characterise the sample. The low angle light scattering detector provides absolute molecular weight; the viscometer detector provides intrinsic viscosity and size; while concentration detector(s) provide concentration and information on composition. The precision on all quantities is typically < 1.0 % RSD, and FIPA run times can be under 5 minutes.

Because of the simplicity, speed, precision and accuracy of the analysis, FIPA is well suited to process development or at-line applications where control of processes requires a fast turnaround time for sequential measurements of the extent of reaction. It is also uniquely suited for high throughput scenarios where the number of samples is simply too great for the analysis times involved in GPC/SEC.

Advantages

FIPA is a simple but powerful technique. It is easily automated because unlike GPC it requires no user intervention and is therefore operator independent. FIPA results are obtained quickly, accurately and precisely - allowing rapid decisions to be made about the product quality or process progress.

Results

Using FIPA, the following results can be obtained:

  • Molecular weight
  • Hydrodynamic size
  • Intrinsic viscosity
  • Concentration
  • Branching
  • Copolymer/Conjugate composition

Table 1: Fully automated FIPA results for a broad polystyrene sample. Analysis repeated every 9 minutes and the data analysed automatically by the OmniSEC software without any user intervention.

Examples

A selection of proven FIPA applications include:

  • Polycarbonate
  • Polyvinyl acetate
  • Polymethyl methacrylate
  • Linear and branched polystyrene
  • Block copolymers
  • Low crystallinity olefin rubber
  • Polyimide
  • Phenolic resins
  • Polyurethane
  • High crystallinity olefin rubber
  • Xylene solubles of polyolefins
  • Polyvinyl alcohol
  • Polyacrylamide

More information

Keywords: Flow Injection Polymer Analysis, Light Scattering Detector, Molecular Size, Polymer,

Other products and services from Viscotek

05/12/2011

Viscotek Gel Permeation / Size Exclusion Chromatography GPC/SEC Range

Gel Permeation Chromatography/Size Exclusion Chromatography (GPC/SEC) is the technique of choice for rapid and reliable characterization of molecular weight and molecular structure for all types of macromolecules – proteins, natural polymers and synthetic polymers.


05/12/2011

Viscotek TDAmax - Temperature controlled GPC/SEC systems

A low angle light scattering detector measuring absolute molecular weight without assumptions, corrections or extrapolation for robust and reliable results. Comprehensive molecular size information down to less than 1nm for full characterization of your protein.


05/12/2011

Viscotek RImax modular GPC/SEC system

The RImax can be upgraded all the way up to tetra detection for absolute molecular weight, size, viscosity, Mark-Houwink, etc all within the same Viscotek system and software environment. The GPCmax includes an autosampler for repeatable and automated sample injection, eliminating operator-to- operator dependency and increasing throughput.


05/12/2011

Zetasizer µV - designed for protein size and protein characterization

Use with cuvettes as batch DLS detector or convert in seconds for use as an SEC detector for absolute molecular size and absolute molecular weight. The Zetasizer µV gives you rapid, accurate and repeatable protein size and molecular weight data for both SEC-LS and cuvette mode. Simply add to a Viscotek or any third party SEC system to use as a superbly sensitive light scattering detector.


05/12/2011

GPC/SEC columns

Selection of the correct column is essential for successful GPC/SEC experiments as obtaining the best chromatographic separation requires a careful match of sample, solvent and column. The solubility of the sample will clearly dictate when you need to use an aqueous or organic eluent.


05/12/2011

Viscotek HT GPC advanced GPC/SEC system for the characterization of polyolefins