This set of connections may be used if an auxiliary function is to be performed, such as 'Hot Water Priority' or where an additional boiler, pump or valve is required.

There are two sets of 'voltage free' terminals situated at the right hand side of the wiring termination block. These switches have both normally open and normally closed sides. Both switches switch simultaneously when power is presented at any one of the auxilliary inputs.

The auxilliary inputs are independent of each other.

These terminals exist to cater for the unexpected control dilemmas that regularly occur during heating installation, and will easily solve many otherwise exasperating problems.

Keywords: Boiler, Terminals

Contact Systemlink

Email - none provided

Print this page

Share

Other products and services from Systemlink

05/12/2011

Products

Systemlink’s zone control products complete the zoning solution, providing independent time and temperature control for optimum comfort and efficiency in all parts of the building. Systemlink’s proprietary central wiring units apply its design philosophy to the electrical installation – uncomplicated layout for trouble-free installation.